OLINK Blog

High-Power DC Chargers for Highway Service Areas

Table of Contents

How to Define Cabinet, Cooling and Expansion Requirements

Choosing high-power DC chargers for highway service areas starts with three connected decisions: how much power the site can supply, what charging performance drivers need, and how the station will expand as demand grows. Together, these determine the cabinet architecture, cooling configuration and long-term installation plan.

From a manufacturer’s perspective, a successful project begins with clear site requirements and model-level technical verification. A charger’s headline kilowatt rating is useful, but it does not establish how the equipment will perform across different vehicles, environmental conditions and simultaneous charging sessions.

Start with Charging Demand and Available Grid Capacity

Highway service areas experience changing traffic volumes, mixed vehicle types and concentrated demand during peak travel periods. Equipment selection should reflect these operating conditions.

Before selecting a charger, buyers should establish the opening and future charging-bay counts, expected vehicle arrivals, typical charging duration and target vehicle mix. Passenger cars, commercial vehicles and coaches can have different requirements for parking layout, cable reach and charging performance.

Available electrical capacity is equally important. The assessment should account for the service area’s other electrical loads and distinguish installed charger capacity from the power available for charging.

For example, four 240 kW chargers provide 960 kW of installed DC output capacity. If the electrical supply allocated to charging is lower, all four cannot continuously deliver full rated output together. Conversion losses and auxiliary consumption must also be considered when determining AC input requirements.

Where installed capacity exceeds available supply, a validated power-management system is needed to limit site demand and distribute power between vehicles. The procurement specification should define both the maximum site input and the expected performance during simultaneous charging.

Match the Cabinet Architecture to the Site Layout

Integrated chargers and split charging systems offer different installation arrangements.

An integrated charger combines power conversion equipment and the charging interface in one enclosure. A split system separates the power cabinets from the vehicle-side dispensers, allowing equipment placement to follow a different site layout.

Selection factorIntegrated chargerSplit charging system
Equipment arrangementPower conversion and charging interface in one enclosureSeparate power cabinets and dispensers
Space requirementsCabinet footprint and service access at charging positionsDedicated cabinet space, dispenser locations and interconnecting routes
Power allocationDepends on the individual charger designMay support sharing across multiple dispensers
ExpansionAdditional chargers or supported internal upgradesAdditional modules, dispensers or cabinets within verified limits
Fault impactConfirm which outputs a charger fault affectsConfirm which dispensers shared equipment faults affect

An integrated design may suit a project where the equipment footprint and maintenance access fit comfortably within the parking layout.

A split design may be appropriate where smaller vehicle-side dispensers or shared power allocation offer practical benefits. Buyers should confirm the permitted cabinet-to-dispenser distance, cable requirements, distribution losses and installation costs.

A shared cabinet does not automatically provide full rated power to every connected dispenser. Request a power-allocation matrix showing output with one vehicle connected, several vehicles charging and a power module unavailable.

Evaluate Output Across the Target Vehicles’ Voltage Range

The rated power printed on a charger does not describe every operating condition. Actual charging power depends on the charger’s voltage-current range, connector rating, thermal limits, shared power allocation and the vehicle’s charging request.

CharIN’s CCS power-class guidance defines charging capability through voltage, current and power operating ranges rather than a single kilowatt figure. www.charin.global

The basic electrical relationship is:

DC power (kW) = voltage (V) × current (A) ÷ 1,000

At an illustrative operating point of 400 V and 500 A, the theoretical DC power is 200 kW. At 800 V and 500 A, it is 400 kW. These examples explain the relationship; they are not guaranteed charging results or specifications for an OLINK model.

For procurement, request the selected charger’s output curve. Confirm continuous current per connector, available power at relevant vehicle voltages, simultaneous output limits and any temperature-related derating.

If a temporary boost rating is offered, clarify its duration and operating conditions. This helps establish whether a higher-rated charger will deliver a practical benefit for the vehicles expected at the site.

Specify Exactly What the Cooling System Covers

“Liquid-cooled charger” is an incomplete technical description. Cooling may apply to the cable and connector, the power modules or several parts of the system.

Buyers should request a clear description of the cooling architecture and the performance supported by that configuration.

For cabinet and power-module cooling, review how heat is removed and what output can be sustained under the site’s operating conditions. Ambient temperature, direct sunlight, altitude, dust, humidity and salt exposure should all form part of the assessment.

Request the relevant derating curve, ventilation clearances and maintenance schedule. An operating-temperature range alone does not confirm that full rated output is available throughout that range.

For cables and connectors, liquid cooling may be appropriate where continuous current and cable-handling requirements justify it. Selection should follow the validated ratings of the actual cable assembly.

Confirm cable length and reach, continuous and peak current ratings, temperature monitoring, coolant servicing requirements and the response to cooling faults. Replacement procedures and spare-part availability also affect long-term operation.

There is no single kilowatt threshold that determines whether every highway charger requires liquid cooling. Current, operating voltage, environmental conditions and component design must be assessed together.

Where a product is described as “semi-liquid-cooled,” ask the manufacturer to identify which components are included. The term should not be interpreted as confirmation that the entire system is liquid-cooled.

Turn Future Expansion into a Defined Upgrade Plan

Expansion should be documented before the first installation.

Increasing cabinet power, adding dispensers and building additional charging bays are different upgrades. Each has its own technical limits.

Expansion goalRequirements to verify
Increase an existing cabinet’s outputModule slots, busbar capacity, protection, cooling and software limits
Add connectors or dispensersSupported output count, distribution hardware, communication and power-sharing rules
Add charging baysGrid capacity, switchgear, foundations, cable routes, parking layout and control-system capacity

Adding power modules will not remove limits elsewhere in the installation. The dispenser, cable, cabinet busbar or upstream supply may become the next constraint.

A useful expansion proposal should show the opening configuration and the final target. It should identify equipment that can be retained, components that require replacement and work that will interrupt operation.

Reserving space for future foundations, ducts, electrical equipment and maintenance access can reduce disruption when additional capacity is needed.

Confirm the Project Scope Before Requesting a Quote

A meaningful quotation should connect the proposed equipment to the site’s operating requirements.

The following checklist helps buyers and manufacturers establish a common technical basis.

Project itemBuyer informationManufacturer confirmation
Grid connectionVoltage, frequency and available charging capacityInput requirements and maximum demand
Charging demandBay count, traffic assumptions and target vehiclesRecommended cabinet and dispenser arrangement
Output performanceRequired power at relevant vehicle voltagesOutput curves and simultaneous charging limits
Cooling optionsClimate, utilisation and cable-handling needsAvailable configurations for the selected model
Site layoutBay dimensions, equipment positions and cable routesClearances, cable reach and installation-distance limits
ExpansionOpening configuration and future targetUpgrade limits, additional hardware and replacement requirements
CMS integrationPlatform and required functionsExact OCPP version, supported features and test scope
PaymentCountry, provider and terminal requirementsSupported integration and responsibility boundaries
ComplianceDestination market and project requirementsDocumentation covering the supplied configuration
Service supportUptime expectations and local maintenance resourcesWarranty, spare parts and service procedures

OLINK’s DC Charging Station range and Highway EV Charging solutions provide starting points for this review.

The public product catalogue includes high-power equipment described as using semi-liquid cooling. Cooling scope, output capability, connector configuration and expansion provisions should be confirmed against the exact model and technical documentation proposed for the project. olinkevse.com

Validate the Selected Configuration Before Deployment

A sample or pilot installation helps confirm whether the proposed equipment meets project requirements before a larger order.

The test configuration should represent the intended production hardware, firmware, connectors and cooling arrangement. Agree on the test conditions and acceptance criteria in advance.

Vehicle testing should cover representative models from the target market. Where relevant, include different battery-voltage platforms and verify charging initiation, sustained operation and session completion.

Simultaneous charging tests should confirm how power is allocated when several vehicles request energy together. Thermal testing should establish sustained output and derating under agreed conditions.

For connected operation, test authorisation, session records, remote commands, fault reporting and recovery after communication loss. Payment validation should cover the selected terminal, transaction flow and unsuccessful payment handling.

Factory acceptance testing verifies the supplied configuration under defined conditions. Site acceptance testing confirms operation with the actual electrical installation, network, CMS and payment environment.

A matching connector or an OCPP label alone does not establish every aspect of compatibility. Model-level documentation and representative testing provide a stronger basis for procurement.

Common Procurement Questions

Does every highway service area need liquid-cooled charging?

No. The decision depends on continuous current, environmental conditions, utilisation and cable-handling requirements. Review the selected configuration’s validated ratings.

Can a dual-gun charger deliver full rated power to both vehicles?

This depends on the model. Confirm whether the advertised rating refers to total cabinet output or individual connector output, and request the simultaneous charging allocation rules.

Can a station start with lower capacity and expand later?

Yes, where the selected design supports it. Confirm the initial and maximum configurations, upgrade components and upstream electrical provisions before ordering.

Does supporting a connector standard guarantee vehicle compatibility?

No. Electrical operating range, communication implementation, firmware and vehicle behaviour also require verification.

Request a Project-Specific Quote

Planning high-power DC chargers for highway service areas? Share your project location, available electrical capacity, charging-bay layout, target vehicles and expansion plan with OLINK.

These details provide the basis for reviewing cabinet architecture, cooling options, charging performance and integration requirements. The selected configuration can then be confirmed through technical documentation, an agreed testing scope and a project-specific quotation.

Ask For A Quick Quote

We will contact you within 1 working day. Please pay attention to the email with the suffix “@OLINKTEK.com”.

Please enable JavaScript in your browser to complete this form.